Thursday, August 7, 2008

CKD: Exhasut cleaner FA331-10A

Specification

Port siZe: 3/8 Rc
Max. Flow rate: 0.3 m3/min
Max. working temperature: 65 celcius degree
Damping effect: 35 dB and over
Oil mist collection ratio: 99.9% and over
Oil storage capacity: 80 cm3

CKD: Automatic Drain DT3000

Specification

Type: normally open
Working fluid: Drain in compressed air (water or oil)
Working pressure range: 0.1 to 1 MPa
Ambient temperature range: 5 to 60 celcius degree
Applicable air compressor: 0.75 to 15 kW
Port size: 3/8, 1/2 Rc

CKD: Dew point SU301E-C1

Specification

Working fluid: Compressed air
Inlet air pressure: 0.4 to 1.0 MPa
Inlet air temperature: 5 to 50 celcius degree
Ambient temperature: 5 to 50 celcius degree
Standard accessories: Bracket

CKD: Dessicant type air dryer

Dessicant type air dryer

Type without using the heat by a desiccant
Reducing 96% of purge rate maximum by energy saving control.
Remarkably reducing noise level to approx. 35dB (A) by variable exhaust method (CKD comparison).
Power consumption reduced by 1/3 with electronic control system (CKD comparison).
Certain performance verification allowed by digital pressure dew point display.
Footprint remarkably reduced by multi tower type (1/3 to 1/2 CKD comparison).
Filters for inlet and outlet opening are provided as standard.

CKD: Air dryer RD-1.5E-PRT series

Specification
Air inlet-outlet port size: 3/8 Rc
Applicable air compressor: 1.5 kW
Air capacity: 120 l/min
Working fluid: Compressed air
Inlet air temperature: 5 to 40 celcius degree
Ambient temperature: 20 to 25 celcius degree
Working pressure: 0.2 to 0.97 MPa
Refrigerant: R22

CKD: Air dryer GT 5055 Series

Specification
Applicable air compressor: 55 kW
Working fluid: compressed air
Inlet air temp. : 5 to 80 celcius degree
Inlet air pressure: 0.2 to 1.0 MPa
Ambient temp. : 2 to 43 celcius degree
Refrigerant: R407C

CKD: Penumatic cylinder with valve

With valve
As most of cylinders with valves have an integrated combination of directional control valve, metering valve (or speed control valve) and cylinder, it can save the trouble of piping.
As the valve is directly connected to the cylinder, it saves the wasted space between valve and cylinder, and reduces the air consumption.

Medium bore size cylinder with valve CKV2
Stainless steel tube enables high corrosion proof and long service life.
The integration of piping and wiring ports, speed adjuster and manual override onto the top enables easy operations.
Common exhaust is available.
Easy speed adjustment.
2 types of variation, double acting and baffle types.

CKD: Pneumatic cylinder

Standard Type

The most widely used cylinder
The inside diameter of tube is available with a size from 2.5 to 250, and this cylinder can be used with wide variations from simple use to applicable use.

Pencil shaped cylinder SCP *2

Light weight and small size
5 types of bore size, 2.5 to 16 mm.
Double and single acting, extend, retract, low speed and heat resistance types are available.
Wide cylinder switch variation.
Corresponding to copper and PTFE free as standard.

CKD: Rotary clamp cylinder double acting spatter adherence prevention type



Spatter adherence prevention has been incorporated in the RCC2 Series configured of the square space-saving cylinder with the built-in rotary clamp mechanism.

Features:
* A fiber aggregate (lube keeping structures) impregnated with spatter adherence prevention agent is used to prevent spatter from sticking and solidifying onto the piston rod during arc welding.
* A metal scraper (coil scraper) helps remove spatter adhering to the piston rod.
* The spatter adherence prevention agent is supplied steadily for a long time, improving durability over general cylinder used in spatter environments.

Specification

Actuation: Double acting
Max. working pressure: 1 MPa
Ambient temperature: -10 to 60 celcius degree (no freezing)
Working piston speed: 50 to 200 mm/s

CKD: High corrosion proof flow control valve FMD00 Series



This microflow adjustment valve has been designed to enable use with highly corrosive fluids.

Features:
* Easy one-push lock
* Easy one-push lock operation minimizes deviation in the flow rate.
* Adjust microflow accurately

Specifications:
Working fluid: Deionized water, chemical liquids, air or N2 gas
Fluid temperature: 5 to 80 celcius degree
Working pressure range: 0 to 0.3 MPa
Ambient temperature: 0 to 40 celcius degree
Mounting attitude: free

CKD: Air operated valve for high vacuum AVB 17 series


Specifications
Working fluid: Vacuum and inert gas
Working pressure range: 1.3x10-5 to 1x105Pa
Max. working differential pressure: 0.1 MPa
Fluid temperature: 5 to 60 Celcius degree
Ambient temperature: 0 to 60 celcius degree

CKD: Air unit CXU 10-GFAB3 series

Specification
Working fluid: Compressed air
Working pressure differential range: AC: 0 to 1.0 MPa; DC: 0 to 0.6 MPa
Max. working pressure: 1.0 MPa
Fluid temperature: AC: 5 to 60 celcius degree; DC: 5 to 40 celcius degree
Ambient temperature: AC: 5 to 60 celcius degree; DC: 5 to 40 celcius degree
Rated voltage: 100 VAC, 24 VDC

CKD: Flow sensor for water WFK3004S-10

Technical Data

Flow rate range: 0.5 to 4.0 L/min
Port size: Rc3/8
Connection section material: Stainless steel SCS 13
Working fluid: clean water and industrial water
Max. working pressure: 1.0 MPa
Ambient Temperature: 0 to 50 celcius degree (85% RH or less)
Fluid temperature: 1 to 70 celcius degree

Friday, August 1, 2008

CKD: Pre filter AF 5000



AF 5016P-50
Treating air flow rate : 16 m3/min
Working fluid : compressed air
Working pressure : 0.08 to 1.0 MPa
Withstanding pressure : 1.5 MPa
Ambient temperature range : 5 to 60 Celcius degree

CKD: Line FIlter AF



AF1003*-20
Treating air flow rate : 3 m3/min
Working fluid : Compressed Air
Working pressure range : 0.1 to 1.0 MPa
Withstanding pressure : 1.5 MPa
Differential pressure indicator : Provided as standard
Drain separator : Integrated

Thursday, July 31, 2008

CKD: Refrigerated Dryer GX5000




GX5004
Applicable air compressor: 3.7 kW
Rated treated flow rate: 0.5 m3/min
Rated Inlet air temperature: 55 Celcius degree
Rated Inlet air pressure: 0.7 MPa
Rated ambient temperature: 32 Celcius degree
Power: 0.22 kW
Refrigerant: R22

CKD: Refrigerated Dryer GX3000




GX 3037
Applicable air compressor: 37 kW
Working fluid: Compressed Air
Rated Treated Flow Rate: 6.6/7.3 m3/min
Rated Inlet Air temperature: 35 Celcius degree
Rated Inlet Air pressure: 0.7 MPa
Rated Ambient temperature: 32 Celcius degree
Dimension: 1040x670x420